TSC - BUTTON COMMANDS
POWER ON UTILITIES - ONLY USE THESE COMMANDS IF YOU KNOW WHAT YOU ARE DOING.
1. Ribbon Sensor Calibration and Gap/black
mark sensor calibration
§
Turn off the power. Press and hold the FEED
button
§
Then turn on printer power.
§
Release the button when LED becomes RED with
blinking
§
ACTION: Printer will feed label and calibrate
the sensor
2. Self-test and dump mode
§
Turn off the power. Press and hold the FEED
button
§
Then turn on printer power.
§
Release the button when LED becomes AMBER with
blinking
§
ACTION: Printer will print self-test information
then enter the dump mode. Feeds some blank and some info on labels.
3. Printer initialization
§
Turn off the power. Press and hold the FEED
button
§
Then turn on printer power.
§
Release the button when LED becomes GREEN with
blinking.
§
Printer will restore settings to default.
§
ACTION: Does not feed labels.
4. Set black mark sensor as media sensor and
calibrate the black mark sensor.
§
Turn off the power. Press and hold the FEED
button
§
Then turn on printer power.
§
Release he button when LED becomes GREEN/AMBER
with blinking.
§
Printer will calibrate the black mark sensor
§
ACTION: Printer feeds blank labels
5. Set gap sensor as media sensor and
calibrate the gap sensor
§
Turn off the power. Press and hold the FEED
button
§
Then turn on printer power
§
Release the button when LED becomes RED/AMBER
with blinking
§
ACTION: Print feeds blank labels
6. Skip AUTO.BAS
§
Turn off the power. Press and hold the FEED
button
§
Then turn on printer power.
§
Release the FEED button when LED becomes solid GREEN
§
ACTION: Printer won't move