TSC-TTP-247 Printer - Manual CommandsAA-00376TSC - BUTTON COMMANDS POWER ON UTILITIES - ONLY USE THESE COMMANDS IF YOU KNOW WHAT YOU ARE DOING. 1. Ribbon Sensor Calibration and Gap/black
mark sensor calibration § Turn off the power. Press and hold the FEED button § Then turn on printer power. § Release the button when LED becomes RED with blinking § ACTION: Printer will feed label and calibrate the sensor 2. Self-test and dump mode § Turn off the power. Press and hold the FEED button § Then turn on printer power. § Release the button when LED becomes AMBER with blinking § ACTION: Printer will print self-test information then enter the dump mode. Feeds some blank and some info on labels. 3. Printer initialization § Turn off the power. Press and hold the FEED button § Then turn on printer power. § Release the button when LED becomes GREEN with blinking. § Printer will restore settings to default. § ACTION: Does not feed labels. 4. Set black mark sensor as media sensor and
calibrate the black mark sensor. § Turn off the power. Press and hold the FEED button § Then turn on printer power. § Release he button when LED becomes GREEN/AMBER with blinking. § Printer will calibrate the black mark sensor § ACTION: Printer feeds blank labels 5. Set gap sensor as media sensor and
calibrate the gap sensor § Turn off the power. Press and hold the FEED button § Then turn on printer power § Release the button when LED becomes RED/AMBER with blinking § ACTION: Print feeds blank labels 6. Skip AUTO.BAS § Turn off the power. Press and hold the FEED button § Then turn on printer power. § Release the FEED button when LED becomes solid GREEN
§ ACTION: Printer won't move |